Abstract
The effects of excipients on the accuracy of tablet subdivision are severely underinvestigated. In this study, placebo tablets were prepared using a combined mixture design of fillers and binders to evaluate the effect of these excipients on subdivision accuracy. The responses assessed were mass loss, mass variation, tablet fragmentation, and increased friability. Dicalcium phosphate dihydrate (DCP) gave rise to more uniform and denser tablets than microcrystalline cellulose (MCC), thus resulting in greater subdivision accuracy. The binder type, hydroxypropylcellulose (HPC) or polyvinylpyrrolidone (PVP), did not affect the subdivision of DCP tablets. On the contrary, the structural similarity between HPC and MCC led to improved subdivision accuracy for MCC tablets. A less accurate subdivision was observed in tablets prepared with a DCP–MCC combination; this finding could be attributed to irregular binder distribution in this matrix. An optimized response was built using desirability analysis. This study helps to illuminate the relationship between fillers and binders to guide formulation scientists in the development of tablets with better subdivision performance.
References
Teixeira M, Sá-Barreto LCL, Gratieri T, Gelfuso GM, Silva ICR, Cunha-Filho MSS. Key technical aspects influencing the accuracy of tablet subdivision. AAPS PharmSciTech. 2017;18(4):1393–01.
Quinzler R, Gasse C, Schneider A, Kaufmann-Kolle P, Szecsenyi J, Haefeli WE. The frequency of inappropriate tablet splitting in primary care. Eur J Clin Pharmacol. 2006;62(12):1065–73.
Nidanapu RP, Rajan S, Mahadevan S, Gitanjali B. Tablet splitting of antiepileptic drugs in pediatric epilepsy: potential effect on plasma drug concentrations. Pediatr Drugs. 2016;18(6):451–63.
Sovany T, Kása P, Pintye-Hódi K. Modeling of subdivision of scored tablets with the application of artificial neural networks. J Pharm Sci. 2010;2:905–15.
Shah RB, Collier JS, Sayeed VA, Bryant A, Habib MJ, Khan MA. Tablet splitting of a narrow therapeutic index drug: a case with levothyroxine sodium. AAPS PharmSciTech. 2010;11(3):1359–67.
Gupta A, Hunt RL, Khan MA. Influence of tablet characteristics on weight variability and weight loss in split tablets. Am J Health-Syst Pharm. 2008;65(24):2326–8.
Ito A, Dobashi Y, Sugihara M. The relationship between dividing properties of scored tablets and dynamic characteristics of various mixed powders. Chem Pharm Bull. 1993;41(3):590–4.
Odsei-Yeboah F, Zhang M, Feng Y, Sun CC. A formulation strategy for solving the overgranulation problem in high shear wet granulation. J Pharm Sci. 2014;103:2434–40.
Morkhade DM. Comparative impact of different binder addition methods, binders and diluents on resulting granule and tablet attributes via high shear wet granulation. Powder Tech. 2017;30:114–24.
Joneja SK, Harcum WW, Skinner GK, Barnum PE, Guo J-H. Investigating the fundamental effects of binders on pharmaceutical tablet performance. Drug Dev Ind Pharm. 1999;25(10):1129–35.
Morin G, Briens L. A comparison of granules produced by high-shear and fluidized- bed granulation methods. AAPS PharmSciTech. 2014;15:1039–48.
Acknowledgments
This research was supported by the Brazilian agency CAPES.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Pereira, G.R.S., Taveira, S.F., Cunha-Filho, M. et al. The Effects of Fillers and Binders on the Accuracy of Tablet Subdivision. AAPS PharmSciTech 19, 2929–2933 (2018). https://doi.org/10.1208/s12249-018-1144-7
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1208/s12249-018-1144-7